Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 |
Display |
Digital: 6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating temperature |
-10°C to + 50°C |
Storage temperature |
-40°C to + 60°C |
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery life |
400 hours typical, without backlight |
Accuracy Specifications |
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/resolution |
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range/resolution |
600.0 V / 0.1 V |
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz) |
AC millivolts1 True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz) |
AC volts1 True RMS |
Range/resolution |
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz) |
Continuity |
Range/resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer. |
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9% + 1 |
Range/Resolution |
40.00 MΩ / 0.01 MΩ |
Accuracy |
5% + 2 |
Diode Test |
Range/resolution |
2.00 V / 0.001 V |
Accuracy |
0.9% + 2 |
Capacitance |
Range/resolution |
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF |
Accuracy |
1.9% + 2 |
Range/resolution |
> 1000 μF |
Accuracy |
5% + 20% |
Lo-Z Capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
Temperature²
(Type-K thermocouple) |
Range/resolution |
-40°C to 400°C / 0.1°C |
Accuracy |
1% + 10² |
Range/resolution |
-40°F to 752°F / 0.2°F |
Accuracy |
1% + 18² |
AC μA true-rms (45 Hz to 500 Hz) |
Range/resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.5% + 3 |
DC μamps |
Range/resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.0% + 2 |
Hz (V or A input)² |
Range/resolution |
99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |