Specification
|
NTS-6
|
S-1
|
S-2
|
S-5
|
S-10
|
S-20
|
Measuring range
(at the time of Track)
|
3.0~100
mN・m
|
3.0~200
mN・m
|
0.030~0.5
N・m
|
0.030~1
N・m
|
0.030~2
N・m
|
Accuracy
|
±1 %
|
2 mN・m or Less ±3dijit
|
0.2 N・m or Less ±3dijit
|
Rotational frequency
(at the time of no-load)
|
85rpm
|
25rpm
|
13rpm
|
18rpm
|
18rpm
|
Display
|
The 4 figures digital display of LCD
|
The measurement direction
|
CW-CCW Possible (right and left) It rotates by the motor.
|
Measuring
mode
|
Peak operation mode (PP):
Display the maximum under measurement .
|
Truck mode (GO):
Always display the load torque which has started.
|
RG mode (PD):
Carry out the data output of the load torque every 1/ 87 seconds.
|
Measurement start time
|
Time after beginning rotation until it starts measurement is set up
(0.1 - 1 second).
|
Torque judging
|
It is in measuring range and a setup of a maximum value and a minimum value is possible.[ O.K. In the Set point ] Lamp lighting : [ NG Outside the Set point ] Error buzzer
|
External input and output
|
Signal output (open collector): O.K., NG
Data output: ASCII Format (baud rate9600), External start switch input
|
Power supply
|
AC100V~240V
|
bit size
|
φ 4
|
HEX6.35
|
Outside size indicator
|
165(W)×110(D)×58(H)
|
Outside size detector
|
φ28×155
|
φ37×195
|
φ40×235
|
Accessories
(one piece each)
|
Inspection report, Proofreading certificate, Traceability system figure
|