DC voltage
|
60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
|
AC voltage 45 to 65 Hz
|
60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy: ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
|
DC + AC voltage 45 to 65 Hz
|
6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy: ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
|
Resistance
|
60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt.
|
DC current
|
600.00 μA to 600.00 mA, 4 ranges
Basic accuracy: ±0.05 % rdg. ±5 dgt.
|
AC current 45 to 65 Hz
|
600.00 μA to 600.00 mA, 4 ranges
Basic accuracy: ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
|
AC Current (use with Clamp on probes) 40 to 1 kHz
|
10.00 A to 1000 A, 7 ranges
Add the Clamp on probe accuracy to Basic accuracy: ±0.6 % rdg. ±2 dgt.
(True RMS, crest factor 3)
|
Peak
|
DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement:
Signal width 1 msec or more (single), 250 μsec or more (repeated)
|
C (capacitance)
|
1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
|
Continuity Check
|
Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
|
Diode test
|
Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages
|
Frequency
|
AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt.
|
dB conversion
|
Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV)
|
Temperature (thermocouples)
|
K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C
|
Other functions
|
Filter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion
|
Display
|
Main and sub displays: 5-digits LCD, max. 60000 digits
|
Display refresh rates
|
5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
|
Power supply
|
LR6 (AA) alkaline batteries × 4, Continuous use: 100 hours
|
Dimensions and mass
|
93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries)
|
Accessories
|
Test Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4
|