Rated output voltage
|
DC 50 V
|
DC 125 V
|
DC 250 V
|
DC 500 V
|
DC 1000 V
|
Effective maximum indicated value
|
100 MΩ
|
250 MΩ
|
500 MΩ
|
2000 MΩ
|
4000 MΩ
|
Accuracy 1st effective measuring range MΩ
|
±4% rdg.
0.200 to 10.00
|
±4% rdg.
0.200 to 25.0
|
±4% rdg.
0.200 to 50.0
|
±4% rdg.
0.200 to 500
|
±4% rdg.
0.200 to 1000
|
Lower limit resistance
|
0.05 MΩ
|
0.125 MΩ
|
0.25 MΩ
|
0.5 MΩ
|
1 MΩ
|
DC voltage measurement
|
4.2 V (0.001 V resolution) to 1000 V (1 V resolution), 4 ranges,
Accuracy: ±1.3% rdg. ±4 dgt., (Ranges in excess of 1000 V are not guaranteed for accuracy.)
|
AC voltage measurement
|
420 V (0.1 V resolution)/600 V (1 V resolution), 2 ranges, 50/60 Hz,
Accuracy: ±2.3% rdg. ±8 dgt., (Ranges in excess of 600 V are not guaranteed for accuracy.)
|
Display
|
Semi-transmissive FSTN LCD with back lighting, Backlight
|
Response time
|
Insulation resistance range: 1 second, PVΩ function: 4 seconds (based on in-house tests)
|
Other functions
|
Live circuit indicator, automatic electric discharge, automatic DC/AC detection, comparator, drop proof, auto power save
|
Power supply
|
AA alkaline batteries (LR6) ×4, Continuous operating time: Approx. 20 hours (based on in-house tests)
|
Dimensions and mass
|
159 mm (6.26 in) W × 177 mm H (6.97 in) H × 53 mm (2.09 in) D, Approx. 600 g (21.2 oz) (including batteries, excluding test lead)
|
Accessories
|
TEST LEAD L9787 ×1, Neck strap ×1, Instruction manual ×1, AA alkaline batteries (LR6) ×4
|