W5 Optical Emission Spectrometers (Arc/Spark-OES)
The 4th Generation High Performance Metal Analyzer
Summary
W5 Optical Emission Spectrometer bring in the advanced technology from the USA. It is the 4th generation Arc/Spark-OES with high performance lowing operating cost for metal analysis and this is the latest research and development of detection equipment. The overall optical design has been enhanced, and with improvements of CMOS technology used to further improve the performance of the W5 while retaining the major benefit of earlier units. The CMOS spectrometer is not only contain the full spectrum characteristics of CCD spectrometer but also the extremely low detection limit for non-metallic elements such as C, S, P, B, As, N etc. The operation is simple and easy to learn. The test result is stable and accuracy. It is a good choice of all common metals for incoming and outgoing product quality control.
Scope of supply
-
Supply list
No. |
Item |
Specifications |
QTY |
Unit |
Remarks |
1 |
Optical Emission Spectrometer |
W5 |
1 |
Set |
Include in quotation. |
2 |
Business computer |
|
1 |
Set |
3 |
Printer |
|
1 |
Set |
4 |
Tungsten electrode |
|
1 |
Pc |
5 |
Electrode pressure spring |
|
1 |
Pc |
6 |
The electrode fixed screw |
|
2 |
Pcs |
7 |
Electrode brush |
Φ6 |
2 |
Pcs |
8 |
Lens holder sealing ring |
Φ16×2.65 |
2 |
Pcs |
9 |
Lens holder sealing ring |
Φ72×2.65 |
1 |
Pc |
10 |
Exhaust gas filter core |
|
1 |
Pc |
11 |
Degreasing cotton |
|
15 |
G |
12 |
Power socket |
|
1 |
Pc |
13 |
M2 Internal hexagonal wrench |
|
1 |
Set |
14 |
M4 Internal hexagonal wrench |
|
1 |
Set |
15 |
Long handle phillips screwdriver |
|
1 |
Pc |
16 |
13-15 fixed wrench |
|
1 |
Pc |
17 |
Spark machine screw |
M6 |
4 |
Pcs |
18 |
Fuse |
10A |
2 |
Pcs |
19 |
Argon gas pressure reducing valve |
|
1 |
Pc |
20 |
Argon gas pipeline |
|
2 |
M |
21 |
Exhaust pipe |
|
1 |
Pc |
22 |
Gas bottle |
|
2 |
Pcs |
23 |
Print paper |
|
1 |
Pc |
24 |
Spectrometer manual |
|
1 |
Set |
Notes: The Buyer knows and agrees that the Seller may adjust the supply when the production of the above-mentioned instruments, spare parts and other suppliers change due to technological progress, product upgrading, market changes, etc.
-
Optional items:
Optional item |
Qty |
Note |
High purity argon gas (pure ≧ 99.999%) |
1 bottle |
Should prepare by customer. If can’t get should use argon purifier to get 99.999% argon gas. |
Small air conditioning |
1 set |
Essential, customer should prepare by themselves. |
High precision magnetic saturation voltage stabilizer (1KVA) |
1 set |
Need for voltage instability, if the customer uses intermediate frequency furnace, then need 3KVA Voltage Stabilizer |
Argon purifier |
1 set |
When argon gas is not as pure as 99.999%. |
Samples grinder (ferrous metals) or Mini lathe (non-ferrous metals) |
1 set |
Essential |
Type samples |
pieces |
Essential for foundry |
Note:
The instrument is calibrated with limited standard samples which Wuxi Jinyibo Instrument Technology Co.,Ltd have for general purpose. For special alloy and special elements, the instrument must be calibrated by customer themselves. Or if customer is willing to provide sample collaboration for program development, the customer must provide accurate sample element content tables and ensure sample uniformity, but such curves are not used as acceptance indicators of the instrument.
Technical Data of W5
-
Parameter
Item |
Index |
Optical system |
Optical structure |
The Paschen Runge construction full vacuum type optics system |
Room temperature |
35℃±0.5℃ |
Wavelength range |
165~589nm (Extendable) |
Focal length |
400mm |
Grating line |
2400m1/mm |
First order spectral line dispersion rare |
1.2nm/mm |
Detector |
Multi block high performance linear CMOS array |
Average resolution ratio |
10pm/pixel |
Excitation table |
Gas |
Rushing argon (99.999%) |
Argon flow rate |
When excited: 3-5L/min
Standby time: no need for standby traffic
|
Electrode |
Tungsten electrode technology |
Purge |
Automatic purge function |
Make up |
Thermal deformation self-compensation design |
Analyze the gap |
Sample stage:3.4 mm |
Excitation light |
Type |
HEPS |
Frequency |
100-1000HZ |
Discharge current |
1-400A |
Special technology |
Optimization of discharge parameters design |
Pre -combustion |
High-energy pre-combustion technology |
Processor |
High end ARM, high-speed data synchronization acquisition and processing |
Data collection system |
Interface |
Ethernet data transmission based on DM9000A |
Power |
220VAC 50/60Hz(Customized) |
Others |
Base |
Fe, Cu, Al, Ni, Co, Mg, Ti, Zn, Pb, Sn, Ag, Mn, Cr etc |
Power consumption |
Maximum:750W standby:100W |
Working temperature |
10-35℃(temperature ≥5°C) |
Working humidity |
20-85% |
Dimension |
860mm(L)*680mm(W)*438mm(H) |
Weight |
About 100Kg |